Websites

Atelier Multidécor: The Outage Only a Monitor Could See

An outage alert kept firing on the Atelier Multidécor site while visitors saw nothing wrong. How we found the cause, what we fixed and the speed gained.

An outage alert that fires several times a day, with no customer complaining, ends up being ignored. That is what settled in during the summer of 2026 on the site of Atelier Multidécor, which has built custom kitchens and cabinetry in Saint-Siméon-de-Bonaventure, in Quebec’s Gaspésie region, since 1994. Telos Machina hosts and maintains the site on Cloudflare Workers, a service that runs a website across servers spread around the world.

Visitors lost nothing: more than 800 real visits completed without an error during the alert hours. But the defect existed, and it had to be found before the alert, by crying wolf, turned into background noise. This piece documents the diagnosis, the fix and the speed work that came with it. It contains no traffic, ranking or revenue numbers. That data is tracked elsewhere.

The monitor that cried wolf

The uptime monitor, the tool that visits the site at regular intervals to confirm it answers, has watched ateliermultidecor.com since July 13, 2026. From that date on, the alert kept coming back several times a day, always the same message: a 48-second timeout exceeded. Never an error code. Never a refused connection.

Every time we checked the site by hand during an alert, it answered normally, in a fraction of a second. The simplest explanation in this kind of situation is that the monitor itself has a problem: network, name resolution, or a misconfigured tool. Three checks closed that line of inquiry.

Seven other sites watched by the same tool, from the same container, with the same DNS resolution and the same Cloudflare address, stayed at 100% uptime through the entire window: the Telos Machina site, the Gazon Net site and five more, client sites and internal tools. DNS resolution for the Atelier Multidécor site was byte-for-byte identical to the healthy sites. All eight monitors shared the same check interval, timeout and retry count. The monitor was not at fault.

An outage real visitors never saw

The second theory was more worrying: that the site really did slow down at times, and ordinary visitors paid for it without complaining. Cloudflare’s own network logs settled the question the other way.

During the hours when every monitoring probe sat stuck, more than 800 real requests completed successfully in that same hour, with zero errors. The site stayed up for every visitor. Only the probe waited without ever getting an answer.

The signal in the execution logs

The answer sat in the execution logs of the Worker, the small program that handles every request on Cloudflare’s network. Every stuck call showed the same fingerprint: about 78 seconds of waiting, about 5 milliseconds of actual compute, and no sub-request completed. A visitor who closes the page mid-load leaves a very different trace, around half a second on both numbers.

The hourly count of stuck calls matched the hourly count of monitor alerts exactly: three stuck calls at 2 PM against three alerts, nine against nine at 3 PM, ten against ten at 4 PM, zero against zero between 10 AM and 1 PM. A matching number in two separate systems stops being a coincidence.

The cause: a program waiting on itself

Once found, the cause fit in one sentence. The versions of the hosting adapter released before the fix make the Worker call itself through an ordinary web request, to service its own page-refresh queue, the mechanism that keeps a page current without rebuilding the whole site on every visit.

Cloudflare does not allow that kind of call. A Worker cannot invoke itself through a plain web request on the same account. The request sat waiting forever, which matches the signature we saw: almost no compute, no completed sub-request, a timeout that finally expires on the visitor’s side instead of the server’s. The corrected version replaces that self-call with an internal mechanism built for this kind of communication.

Why this kind of diagnosis matters

A plumber who doesn’t know why a pipe is leaking patches the visible symptom and waits for the next leak. The same shortcut exists in web hosting. Without the Worker’s execution logs, the easiest move would have been to blame the monitor, turn down the alert frequency, or write the failures off as noise.

None of those three moves would have fixed anything. The Worker would have kept hanging on the same requests. The diagnosis cost log-reading time instead of a quick patch. That is the trade we make every time a signal doesn’t mean what it looks like it means.

The trap in a clean run

The fix itself moved fast once the cause was known: update the hosting adapter and Next.js, the engine behind the site. Confirming it took longer, and nearly fooled the team three separate times.

Every new deploy resets every running copy of the site worldwide. A clean stretch right after a deploy proves nothing: it would look the same whether the fix worked or not. The discipline we settled on was to first measure the best clean stretch the old, unfixed code had managed between two incidents: 30 hours and 23 minutes. The fix counted as confirmed only on the day it beat that number, July 30, at 46 hours and 44 minutes without an incident.

A stricter bar, seven straight days with no deploy at all, had not been met at our last reading in early September 2026: the site keeps changing, and every new deploy resets the clock. A site under active work may never clear that kind of bar.

A security gap closed along the way

The update fixed something else on its way through. The site was running a version of Next.js below the floor Telos Machina requires on its own sites, because of a known flaw in language handling that lets an attacker bypass certain bilingual routing rules. The new hosting adapter needs a more recent version to run at all, which put the site back above that floor.

The phantom outage and the security flaw were closed in the same deploy, on July 27, 2026. Two unrelated problems, fixed by the same version bump. That doesn’t happen often, so it is worth writing down.

The rest of the work: speed, images and structure

Diagnosing the phantom outage was only part of the job. A series of speed and image fixes followed, each measured before and after. LCP, the time it takes the largest visible element on a page to render, is the metric Google uses to judge how fast a page feels. Lighthouse is Google’s free tool that scores a page’s speed and accessibility.

Metric Before After
Accessibility score (mobile Lighthouse) 96 100
Home page HTML weight 333,283 bytes 86,042 bytes
Header image (AVIF, a compact image format) 253 KB 25 KB
Preloaded fonts 10 4
Home page LCP (logo fix) 7.1s 6.4s
Town-page LCP (main image loaded with priority) 5.1s 3.8s
Mobile Lighthouse score, town page 79 88

Most of the HTML weight cut came from a translation file that loaded both of the site’s languages at once instead of only the one requested. The ten fonts preloaded at the start weighed 376 kilobytes together and slowed down the largest visible element instead of speeding it up, the opposite of what preloading is meant to do. Four fonts remain.

A separate bug caused a loop on unknown site addresses: every missing page replayed a redirect twenty times over before stopping, on every single load. Fixed September 2.

The sitemap, the file that lists every page for search engines, held 64 addresses on August 5. It held 92 in early September 2026, including twelve pages built for individual towns across Gaspésie and the Bas-Saint-Laurent, each written for its own location rather than copied from one town to the next. The site also received the technical structure Telos Machina runs on its own pages: structured data per page, French-English correspondence for search engines, automatic submission of new addresses, and open access for content-reading bots instead of the reflexive blocking many sites apply today. Eighteen real photographs of pieces built in the shop replaced generic or AI-generated images across the main pages in early September.

What to ask the person who maintains your site

When an alert comes back more than once, ask that it be followed to its cause, and ask which baseline will be used to confirm the fix. An alert that returns with no known cause deserves an investigation before any sensitivity setting is touched. Without that baseline, a fix gets judged by feel, and feel follows the last quiet stretch.

FAQ

Did the Atelier Multidécor site actually go down?

Not for its visitors. The uptime monitor reported an outage several times a day, but real visits in the same hour all completed successfully. The defect was real, and it affected the monitoring probe.

What was causing the problem?

A bug in the program that hosts the site on Cloudflare’s network, present in the versions released before the fix. That program was calling itself to service its own page-refresh queue, an operation Cloudflare does not allow between two copies of the same site. The request sat waiting for a reply that would never arrive.

Would a business owner ever notice a bug like this?

Rarely. It doesn’t crash the site for a customer browsing normally. It hides in hosting logs and in the behavior of an external monitoring tool, which is why it can run for weeks unnoticed.

Where can I see the search results from this project?

Not here. This piece documents what was diagnosed and fixed on the site itself. Search-visibility numbers are tracked elsewhere and are not part of this article.

We fix this kind of outage with the same discipline documented here: establish what a system is actually doing before deciding how to fix it. Our websites page covers how we approach hosting and speed for a hands-on trade business.

  • case study
  • website
  • SMB
  • Gaspésie
  • Cloudflare Workers

Ready to automate?

We identify your most costly process, build the automation, and show you the results.

Talk to an expert